Configuration Options.
Network Management Card (NMC) Password Reset Procedure. Issue. Forgotten or lost Network Management Card (NMC) Password. This article applies to Network Management Card 1 and 2, as well as any devices that contain an embedded version of these cards such as a Rack Power Distribution Unit (PDU) or Rack Automatic Transfer Switch (ATS). Product Line. Devices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9. TH)Network Management Card 1 - AP9. AP9. 61. 8, AP9. 61. Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP7.
XX, AP7. 9XX), Rack Automatic Transfer Switches (AP7. XX, Environmental Monitoring Units (AP9. AP9. 34. 0, Netbotz 2. Network Management Card 2 - AP9. AP9. 63. 0CH, AP9. AP9. 63. 1CH, AP9. CHDevices with an embedded Network Management Card 2 include (but are not limited to): 2.
G Metered/Switched Rack PDUs (AP8. XX, AP8. 6XX, AP8. XX, AP8. 9XX), Certain Audio/Video Network Management Enabled products.
Ap9617 Management Card Manual In regards to Network Management Card 1 (AP9617, AP9618, AP9619) or devices Please refer to the user's manual if you are not sure or your device is not. Schneider Electric: the global specialist.
- UPS Configuration Overview The UPS menu’s Configuration option provides access to the configurable parameters described in the following sections.
- AP9618, AP9619, AP9630, AP9631, AP9635) with a firmware version of 3.3.1 or later, or a Symmetra PX2 (which has an internal Network Management Card, OG. Upgrading enables you to retain your existing configuration settings.
- Read real-world reviews of APC AP9619 by millions of IT pros. Get answers to your questions in minutes.
- Schneider Electric StruxureWare for Data Centers DCIM support community and help center. Sign up to ask and answer questions from DCIM professionals.
- Catalyst 3560G-24TS Switch: Access product specifications, documents, downloads, Visio stencils, product images. Configuration Examples and TechNotes. Spanning Tree Protocol. Spanning Tree PortFast BPDU Guard Enhancement.
- Issue How can I mass configure or configure multiple Network Management Card devices? Product Line Network Management Card 1 (NMC1) - AP9617, AP9618, AP9619.
- APC AP9619 - Web Management Card - No Response. Hardware Thread, APC AP9619 - Web Management Card - No Response in Technical; Anyone else got an. This will give you full access to all the menu's for configuration or.
Browse the steps below for your device model in order to reset the administrator's password. Note: Connecting a non- APC serial cable during the procedures below can cause unwanted erratic device behavior.
Web/SNMP Card & Network Management Card 1 Procedure In addition, if you are trying to reset a password on a UPS that has more than one Smart. Slot accessory installed in it (i. AP9. 60. 7 interface expander), it may be required to temporarily remove the other Smart.
Slot accessories to gain direct serial access to the NMC console interface. Please reference that accessory's user guide on how to do that. It is also important to make sure that the accessories are installed in the correct order, referencing this document. Select a serial port at the local computer, and disable any service that uses that port. Refer to the chart below and obtain the correct communication cable for the Network Management Card 1 enabled device: Device.
Configuration Cable Part Number. Most UPSs with a DB- 9 style serial port. DB- 9 to DB- 9)Rack PDU (AP8. XX*, AP8. 6XX*, AP8. XX*, AP8. 9XX*, AP7. XX, AP7. 9XX)9. 40- 0.
RJ- 1. 2 to DB- 9)1st Generation Rack Automatic Transfer Switch (AP7. AP7. 70. 1, AP7. 72. DB- 9 to DB- 9)2nd Generation Rack Automatic Transfer Switch (AP7.
XX, excluding 1st Generation SKUs)9. RJ- 1. 2 to DB- 9)Netbotz 2. Environmental Monitoring (AP9. AP9. 34. 0, AP9. 32. DB- 9 to DB- 9)Rack Air Removal Unit (ACF4. ACF4. 02)9. 40- 0.
DB- 9 to DB- 9). * Indicates the device uses NMC2 password reset procedure. Connect the serial cable to the selected port on the computer and to the configuration port at the UPS/Network Management Card Embedded device.
Run a terminal program (such as Hyper. Terminal. If you are unable to display the User Name prompt, verify the following. The serial port is not in use by another application. SCROLL LOCK is off/disabled. The terminal settings are correct as specified in step 3.
The correct cable is being used as specified in step 2. Press the Reset button once. The Status LED will flash rapidly (almost immediately) while alternating between orange and green. Press CTRL+C, log off, reconnect any serial cable you disconnected, and restart any service you disabled.
Note: For Network Management Cards running lower than version 2. AP9. 60. 6), step 6 (the second reset press) will not be necessary. Network Management Card 2 Procedure. Please note: On v.
X. X firmware, the Super User or Administrator level accounts can reset other Administrator, Device, Read Only, and Network Only user passwords. This procedure may not be required if the Super User password or at least one set of Administrator credentials are known. You can use a local computer that connects to the Network Management Card through the serial port to access the command line interface. This port is labeled . You'll also need to press the pinhole reset button - access is located on the front of the Network Management Card to the right of the Ethernet jack. Select a serial port at the local computer, and disable any service that uses that port.
Connect the provided serial cable (APC part number 9. Network Management Card. Run a terminal program (such as Hyper. Terminal. If you are unable to display the User Name prompt, verify the following. The serial port is not in use by another application.
SCROLL LOCK is on. The terminal settings are correct as specified in step 3. The correct cable is being used as specified in step 2. Press the Reset button once (please note, sometimes aligning a paper clip or similar to the pinhole reset button can be difficult. It is suggested to hold the paper clip or similar device towards the top of the reset button hole and press gently until the alignment is made). Wait 5- 7 seconds (the Status LED will be off while you wait) and then after that period of time, the Status LED will flash rapidly while alternating between orange and green.
Press the Reset button a second time immediately while the LED is rapidly flashing - which will cause the LED to then go off - in order to reset the User Name and Password to their defaults temporarily (the default User Name and password are both apc). Press ENTER, repeatedly if necessary, to display the User Name prompt again, then use the default, apc, for the User Name and password.
In addition to possibly neededing to reset its password, you may need to re- enable the account if no other administrative access is available or known. To do that, type: Because the Super User can also reset the password for any account, you can reset other user's passwords as well. For example, to change the password for user upsadmin too, type: user - n upsadmin - pw p@ssword. Type quit or exit to log off, reconnect any serial cable you disconnected, and restart any service you disabled.